Specifications:
- Hermetically sealed stator, anti track self healing stator resin prvents motor burn out
- Removable Water Bloc™ lead connector
- Cable material according to drinking water regulations (VDE/ACS/KTW approved)
- Sand slinger and Mechincal seal for high performance in sand
- High efficiency electrical design for low operation cost
- All motors are prefilled and 100% tested
- Max. storage temperature: -15°C to +60°C
- Non contaminating FES 91 filled design
Technical Specifications:
- 30 to 150 kW
- 8″ NEMA flange
- Starts per hour: max. 10
- Installation: vertical/horizontal
- Standard voltage: 380-415 V/50Hz, 460 V/60Hz
- Voltage tolerance 50 Hz: -10% / +6% UN(380-415V = (380-10%)-(415+6%)
- Voltage tolerance 60 Hz: ±10% UN
- Motor protection: Select thermal overloads according to DIN 61947-4-1, trip class 10 or 10A, trip time <10s at 5 x IN
- Insulation: Class F
- Rated ambient temperature: 30°C
- Cooling flow: min. 0.16 m/s
- Built in Subtrol Heat Sensor (use with SubMonitor)
- Motor lead in 8 metre length (VDE/ACS/KTW approved)
Options:
- Other voltages
- Wye/Star Delta start (pos.of cables 90°)
- Motors in complete 316SS construction
- Pt100 temperature sensors (sold separately)
- 316SS motor with SandFighter Sealing System
Reviews